PARTS LOCATION
ILLUSTRATION
ILLUSTRATION
Remote Up / Down Function does not Operate
DESCRIPTION
When the ignition switch is ON and the window lock switch is off, the multiplex
network master switch sends remote up/down signals to each power window regulator
motor via the LIN communication line.
PROCEDURE
1.
CHECK ...
Generator Signal Circuit
DESCRIPTION
When the engine is started, the generator assembly turns on and a voltage pulse
signal is generated.
This signal is used by the air conditioning amplifier assembly.
The signal expressing the amount of output from the generator assembly is one ...