Toyota 4Runner manuals

Toyota 4Runner: Fuel pump shut off system

To minimize the risk of fuel leakage when the engine stalls or when an airbag inflates upon collision, the fuel pump shut off system stops the supply of fuel to the engine.

Follow the procedure below to restart the engine after the system is activated.

Vehicles without a smart key system

Turn the engine switch to the
“ACC” or “LOCK” position.

Restart
the engine.

Vehicles with a smart key system

Turn the “ENGINE START STOP”
switch off.

Restart the
engine.

NOTICE

Before starting the engine

Inspect the ground under the vehicle.

If you find that fuel has leaked onto the ground, the fuel system has been damaged and is in need of repair. Do not restart the engine.

If you think something is wrong
If you notice any of the following symptoms, your vehicle probably needs adjustment or repair. Contact your Toyota dealer as soon as possible. Visible symptoms • Fluid leaks under the vehicle ( ...

Steps to take in an emergency
...

Other materials about Toyota 4Runner:

Disassembly
DISASSEMBLY PROCEDURE 1. REMOVE FRONT SUPPORT TO FRONT SHOCK ABSORBER NUT (a) Secure SST in a vise. SST: 09727-30021 09727-00010 09727-00031 SST: 09727-00060 (b) Attach the ar ...

Acceleration Sensor Malfunction (C1420)
DESCRIPTION Refer to DTCs C1419 and C1435 (See page ). DTC Code DTC Detection Condition Trouble Area C1420 After the difference between GL1 and GL2 becomes 0.6 G or more with the vehicle stati ...